500V/100A~600A series
750V/100A~600A series
900V/100A~600A series
1000V/100A~600A series
1200V/100A~600A series
Supports multi-channel parallel connection, providing convenient conditions for customers to conduct wide-range tests
AC power input
380V±15% three-phase five-wire system, frequency 50Hz±5Hz
Power quality
Input side power factor > 95%
Input side current harmonics (THD) ≤ 5%
Output side voltage ripple
≤ 0.5%F.S
Main channel
Hardware technology Discharge energy feedback to the power grid
Output voltage measurement and control accuracy ≤0.05%F.S
Output current measurement and control accuracy ≤0.05%F.S
Output current response time ≤15ms (no overshoot)
Charge/discharge conversion time ≤30ms
Minimum data recording time interval 10ms